INSTRUCTION MANUAL
CCD COLOR CAMERA
IK-DF01A
Please read this manual thoroughly before use, and keep it handy
for future reference.
Record in space provided below the Model No.and
the Serial No. as found on the label on the bottom
of this unit.
Model. No. IK-DF01A Serial No.
Retain this information for future reference.
TABLE OF CONTENTS
Important safeguards
1. Features & Description ................................................. 3
2. Cautions........................................................................ 3
3. Components ................................................................. 3
4. Part Names & Functions ............................................... 4
5. Connections and Operations ........................................ 5
6. Installations ................................................................... 7
7. Line Lock Phase ........................................................... 9
8. Note on use and Installation ......................................... 9
9. In Case of Problems ..................................................... 10
10. Specifications................................................................ 11
11. Exterior View ................................................................. 12
• The CAUTION label, shown on the left,
is attached on the camera.
CAUTION TO REDUCE THE RISK OF ELECTRIC SHOCK.
DO NOT REMOVE COVER (OR BACK).
NO USER SERVICEABLE PARTS INSIDE.
REFER SERVICING TO QUALIFIED SERVICE PERSONNEL.
The lightening flash with arrowhead
symbol, within an equilateral triangle,
is intended to alert the user to the
presence of uninsulated “dangerous
voltage”within the product’s enclosure
that may be of sufficient magnitude to
constitute a risk of electric shock to
persons.
WARNING :
TO REDUCE THE RISK OF FIRE OR
ELECTRIC SHOCK, DO NOT EXPOSE
THIS APPLIANCE TO RAIN OR
MOISTURE.
CAUTION :
CONNECT 24V AC UL LISTED CLASS 2
POWER SUPPLY.
The exclamation point within an
equilateral triangle is intended to alert
the user to the presence of important
operating and maintenance (servicing)
instructions in the literature
accompanying the appliance.
FIELD INSTALLATION MARKING :
WORDED :“THIS INSTALLATION SHOULD
BE MADE BY A QUALIFIED SERVICE
PERSON AND SHOULD CONFORM TO
ALL LOCAL CODES.”
Note : The camera is indoor used
INFORMATION
This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules.These limits are designed to provide reasonable protection
against harmful interference when the equipment is operated in a commercial environment.
This equipment generates, uses, and can radiate radio frequency energy and, if not installed
and used in accordance with the instruction manual, may cause harmful interference to radio
communications. Operation of this equipment in a residential area is likely to cause harmful
interference in which case the user will be required to correct the interference at his own expense.
USER-INSTALLER CAUTION : Your authority to operate this FCC verified equipment could be
voided if you make changes or modifications not expressly approved by the party.
- 2 -
1. FEATURES & DESCRIPTION :
IK-DF01A has following function.
(1) Quick install Design- you can manually set the camera direction.
(2) Built in vari-focal lens with auto-iris
Focal length 2.8~5.8mm
(3) Incorporated 1/4type CCD image sensor gives high resolution and excellent
sensitivity
480 lines horizontal resolution
0.5 lx minimum illumination with smoke cover
(4) 50dB Signal-To Noise Patio
(5) Power supply- AC24V or DC12V - This camera automatically detects the power.
(6) BLC, AGC, and Line-Lock (AC24V)
2. Cautions :
(1) In order to protect the camera, avoid placing or using it under direct sunlight, rain or
dust.
(2) Avoid touching the CCD sensor with your fingers. If necessary, use a soft cloth
moistened with alcohol to wipe off any dust.
(3) When the camera is not in use, keep the lens cap attached to protect the CCD
sensor.
(4) Avoid aiming the camera at the sun.
(5) Avoid shooting the camera at intense light. Intense light such as a spotlight may
cause a bloom or smear. A vertical stripe may appear on the screen.
However, this is not a malfunction.
(6) Install the camera away from video noise. If cables are wired near electric lighting
wires or a TV set, noise may appear in images. In this event, relocate cables or
reinstall equipment.
3. Components :
(1) Camera
1
(2) Accessories
(a) Instruction Manual
(b) Installation Screw
1
2
- 3 -
4. PART NAMES & FUNCTIONS :
Power Input Cable
Knockout
Cut with a knife or scissors
and insert the cables through
the knockout so the cables will
not pinched when installed.
Connect the power
cable to AC24V or
DC12V. (RED:+12,
Black:GND)
VIDEO Cable (BNC Tap)
Connect the Video Cable to
a monitor or video device.
The image is outputted
when powered on.
Zoom Lever
Changes the picture range.
Its screw design allows
locking capability.
"Bottom" mark
The "Bottom" mark indicates the
lens position. The "Bottom" mark
should be on the top when installing
in a ceiling.
Focus Lever
Adjusts the image into focus. Its screw
design allows locking capability.
Mode Setting Switch
Lens Iris ADJ
Use to compensate
for the iris level.
1:BLC (Backlight Compensation Control)
Turn towards L (low)
for a darker picture.
Turn towards H (high)
for a brighter picture.
Optimum value is
adjusted at the
When switched on, it
automatically adjusts to
compensate for subjects that
are lit from behind.
2:AGC (Auto Gain Control)
When switched on, it
automatically adjusts the
image in relation to the
brightness of the subject.
default setting.
V Phase ADJ
Adjusts the phase
difference between
this camera and other
cameras when in Line
Lock mode.
3:DC/AES
Not available for this camera.
Be sure to switch to ON.
4: LL (Line Lock)
Use this switch to set the
camera synchronization to
internal or line lock. Line
Lock is available with AC24V
only.
Installation Holes
Installs camera to ceiling with
attached screws.
Tilt ADJ Screws
Lens ADJ Screw
Turn the ring-type screw to adjust the lens pan angle.
Fasten and lock it after completing the adjustment.
Turn the screws to adjust the lens tilt
angle. Fasten and lock them after the
adjustment completes.
- 4 -
5. CONNECTIONS AND OPERATIONS :
Notes on connecting
• Power plugs connected equipment must be disconnected before installations.
• A 75-ohm coaxial cable (3C-2V or 5C-2V) is required for standard connection.
• For details of wiring and operation of equipment to be connected, refer to their
operation manuals.
• Coaxial cables for video signals and the power cord are not supplied with the
camera.
Refer to the operations manuals of connected equipment for detailed wiring and
overall operation instructions.
5-1 Basic connection single system configuration
Video Monitor
( ) POWER CORD (twisted pair line)
AC 120V
minimum wire size of 18 AWG is recommended.
24V AC UL Listed Class 2 power supply / 12V DC power supply
CAUTION : Never input 24V AC and 12V DC at the same time.
In case of DC12V, connect “+12” to red cable and “GND” to black cable.
Do not overload power supply
Since this camera uses 24V AC UL Listed Class 2 power supply or 12V DC power
supply, it should be connected to a power supply that allows for at least 5w
consumption.
- 5 -
5-2 Line-Lock Control
• Matching the vertical synchronization with the power frequency is called the Line-
Lock.
• This function is activated when the SYNC menu is selected to LL.
• When two or more cameras are switched by the video switcher for viewing by a monitor
TV, the vertical sync. phase can be locked with the power frequency, and a stable
vertical sync. is obtained without being disturbed at the time of switching.
Video Monitor
VIDEO SWITCHER
CAMERA1
TO AC 24V UL Listed
class 2 power supply
CAMERA2
Note :
• The camera is synchronized to the power frequency of 60 1Hz covering a normal
fluctuation of the power frequency. However, the camera may not cover a large
fluctuation caused from the power generated by an engine generator, etc.
• It takes about 10 seconds or more until a stable synchronization is obtained after
the power is turned on. This is normal, because several seconds are required to
stabilize the camera against power noise.
• Refer to “7. LINE-LOCK PHASE” for adjustment.
- 6 -
6. Installations :
(1) Turn the cover left to unfasten it.
(2) Connect the cable of the camera and the cable from the designated power supply
with respective BNC connectors.
(3) Fix the camera base to the ceiling firmly with the attached 2 screws. Otherwise it
might drop and cause injury.
Note :
• The camera’s weight is about 290g.
• The attached screws are designed to install the camera to a board.
When installing to a surface of other materials, prepare the screws to fix it firmly.
• The screw diameter is φ4mm.
6-1 Adjust the Angle of View
(1) The lens direction in pan direction can be adjusted by turning ring left to unfasten
1
it without moving the lens. After adjustment, turn the ring
right to fasten it.
1
Note :
• Do not turn the lens over 360°. Otherwise the inner connector may be broken and
the image may not appear.
1
2
4
3
(2) The lens direction at the tilt angle can be adjusted by turning screw
. After
2
adjustment, turn screw
to fasten it.
2
(3) Adjust the zoom position by turning zoom lever . After adjustment, fasten the
3
zoom lever
.
3
(4) Adjust the focus by turning focus lever .After adjustment, fasten the focus lever
.
4
4
(5) Repeat the adjustments from step (1) to step (4) till the optimum image appears.
- 7 -
6-2 Installing to Wall
The camera head at shipping is set for installing the camera to the ceiling. The camera
head angle should be changed when installing to a wall.
Camera Head
2
"Bottom" Mark
1
Tilt Range
(1) Turn 2 screws of
to unfasten the camera head.
1
Note :
• The camera head is connected to the inside with cable, do not pull it with strength.
Otherwise the inner connector may be broken and the image may not appear.
(2) Reverse the camera head 180° from default setting and install it. The direction of
the camera head is shown as above. With the “Bottom” mark
range is adjusted as shown above.
upwards, the tilt
2
(3) Fasten the screw
to fix the camera head.
1
6-3 Installing the Cover
As shown in the illustration, adjust the cover
position to the camera’s installation position and
turn it right to install it.
- 8 -
7. LINE LOCK PHASE
When a video switcher switches two or more cameras, the picture may fluctuate on the
video monitor due to the different AC line phase of each camera. In this case, adjust the
V PHASE controller to get a stable image.
V PHASE CONTROL
8. NOTE ON USE AND INSTALLATION
• Do not aim the camera at the sun
Do not aim the camera at the sun or point it at sun even if you are not shooting.
• Do not shoot intense light
Intense light such as a spotlight may cause a bloom or smear. A vertical stripe may
appear on the screen. However, this is not a malfunction.
• Treat the camera with care
Do not drop the camera or subject it to strong shock of vibration.Otherwise, the camera
may malfunction.
• Never touch internal parts
Do not touch the internal parts of the camera other than the parts specified.Otherwise,
the camera may malfunction.
• Do not splash water on the camera
Install the camera where the camera can be kept dry. If the camera gets wet, turn off
the power and contact your dealer.
• Check the ambient temperature and humidity
Avoid using the camera where the temperature is hotter or colder than specified.
Otherwise, the quality of images may deteriorate or internal parts may be affected.
Special care is required to use the camera at high temperature and humidity.
• Should you notice any trouble
If any trouble occurs while you are using the camera, turn off the power and contact
your dealer. If you continue to use the camera when there is something wrong with it,
the trouble may much worse and an unpredictable accident may occur.
- 9 -
9. IN CASE OF PROBLEMS
Condition
Check Points
No image
• Are the camera and connected equipment turned on?
• Is the mode setting switch DC/AES set to OFF? Be sure to
set to ON.
• Are cables connected correctly?
Unnatural color
• Is the monitor TV adjusted correctly?
• Is the lighting too weak?
The image is out of • Is the lens focus adjusted?
focus.
• Is the lens or cover dirty?
• Are there any large barrier or bright illumination near the
camera?
The image is dark.
• Is the lens iris adjustment volume correctly set?
- 10 -
10.SPECIFICATIONS
1. Image System
Image Device
Pixel Elements
1/4” IT CCD
768 (H) x 494 (V)
2. Electrical
TV System
2:1 Interlace, 15.734KHz Horizontal, 59.94Hz
Vertical
Horizontal Resolution
S/N Ratio
480 TV lines
50dB (TYP. AGC Off, Weight On)
Minimum Illumination
0.2 lux (More than 10% of image output, Clear cover)
0.5 lux (More than 10% of image output, Smoke cover)
Auto Gain Control (AGC)
Iris Control Mode
White Balance
Average AGC (24dB)
Auto Iris Lens
Auto
White Balance Range
2500°K ~ 10000°K
Line lock Vertical phase adjustment Provided (VR : range 300deg)
γ compensation
0.45
Backlight Compensation (BLC) On / Off (DIP-SW)
Video Output Signal
VBS (1.0Vp-p, 75ohm unbalance, BNC)
Synchronizaiton System
Internal for DC or Linelock for AC
3. Mechanical
Weight
290g
Dimension
110mm (φ) x 96mm (H)
4. Optical
Built-in Lens
Vari-focus Lens
f=2.8 ~ 5.8mm, F1.4 : Auto Iris
View Angle
Wide : 97.5° (D), 76.7° (H), 56.8° (V)
Tele : 47.9° (D), 38.2° (H), 28.7° (V)
Focus Length
0.2m ~ ∞
5. Power
Input Voltage
Power Consumption
6. Environmental
Operating Temperature
Storage Temperature
7. Regulation
DC12V or AC24V
3.5W
-10°C~50°C 90%RH max
-20°C~60°C 70%RH max
Safety
UL2044
Emission
FCC Class A / DOC ClassA
- 11 -
11.EXTERIOR VIEW
φ110
83.5
(Unit : mm)
- 12 -
2-hold φ3.2 (1/8") driver,
depth about 40mm.
Wall
2-TP4 X 37
- 13 -
- 14 -
|